Shanghai Baihe Instrument Technology Co., Ltd
Home>Products>ARL direct reading spectrometer
ARL direct reading spectrometer
Product Code: ARL 4460 Product Model: ARL 4460 belongs to the category of Spectrometer - Direct Reading Spectrometer (OES), brand: Thermoelectric, usa
Product details

Introduction to ARL Direct Reading Spectrometer 4460
ARL 4460 current controlled light source (CCS) and time resolved spectroscopy (TRS) technology, combined with factory calibration curve and self diagnosis function, bring analytical technology to a new world. Not only can it perform routine analysis, but it can also meet various complex requirements of metal optical analysis workers. Structural design and manufacturing processes ensure that the instrument has good analytical performance in harsh environments.
1. Stable and reliable hardware
2. Factory calibration curve
3. Spectral manufacturing technology
4. Analysis software
5. Higher analysis accuracy and faster analysis speed
6. New breakthroughs have been made in analyzing trace elements and gas elements
7. Wide analysis range: suitable for analyzing metal materials such as steel, aluminum, copper, magnesium, tin, lead, zinc, precious metals, etc
8. No special requirements for operators
Technical specifications of ARL direct reading spectrometer 4460
1. Optical laboratory design: One meter focal length, Paschenlongge device, vacuum type, constant temperature control (38 ± 0.10C), made of special cast iron material, with a maximum of 60 channels set up
2. Sample stage: argon filled sample stage; Built in self circulating water cooling system
3. Grating: According to the analysis task, the instrument is configured with one of the following three types of gratings
4.1080gr/mm,1667gr/mm,2160gr/mm
5. Resolution: Depending on the grating, exit slit, and spectral level
6. Slot width: Incident slot: 20um; Exit slit: 25, 37.5 , 50 , 75um
7. Photomultiplier tube: Straight diameter of 28mm, 10 level side window tube, optical glass or artificial quartz window
8. Light source: Current controlled light source (CCS)
9. Spectrometer control: APL MMB386 microprocessor using CMOS technology, with state control card; Each channel is equipped with a digital to analog (A/D) converter and attenuator, divided into 41 levels; The dynamic range of the electronic part is directly proportional to the measurement time, usually 2 × 106 counts per second
10.12-digit programmable attenuator
11. Time resolved spectroscopy (TRS)
12. Environmental requirements: Room temperature: 16-300C, maximum allowable temperature difference is 50C/hour; Relative humidity 20-80%
13. Power requirements: single-phase power supply with voltage 230V (+10% -15%) and protective grounding
When the voltage fluctuation exceeds ± 10%, a 5KVA voltage regulator is required. Current 12A, frequency 50 or 60Hz; Power of 2.5KVA; Grounding resistance<1 Ω 15. European standard: 89/392/EEC Low voltage materials, 89/366/EEC Electromagnetic
16. Requirements for argon gas: purity 99.995%, maximum content 5ppm (when analyzing high Si samples, the maximum content is 2ppm)
17. Flow rate of 3.5 liters per minute (during analysis), 0.35 liters per minute (during standby)
18. Geometric dimensions: length 1385 (excluding excitation stage) x width 910 x height 1220mm
19. Length 1690 (excitation table) x width 910 x height 1220mm
20. System weight: approximately 540 kilograms
21. Auxiliary equipment: argon purifier, bottled argon gas distribution system, voltage stabilizer prototype
 

Relying on years of accumulated international standard library, each curve is established from dozens of standard samples, with more data points than the analysis curves established on site.
The unique calibration software can not only correct spectral interference, but also deduct background interference, improving the accuracy of analysis results, with an accuracy (relative standard deviation) better than 1%.
Saved users the cost of purchasing standard samples.

Spark data acquisition and processing system SPARK-DAT (optional)
Traditional direct reading spectrometers can only obtain elemental information in metal materials. Scanning electron microscopy is usually used to investigate the microstructure and chemical reactions between elements. The ARL 4460 metal analyzer equipped with single spark data acquisition and processing technology SPARK-DAT can not only perform elemental analysis, but also achieve inclusion analysis. This technology is mainly used for:
1. Phase analysis (such as acid soluble aluminum and acid insoluble aluminum in steel)
2. Analysis of inclusions in steel: such as CaO, Inclusions in CaS aluminum, such as TiB2, MgO
3. Cleanliness analysis
4. Improve the analytical performance of trace elements

WinOE analysis software
WinOE running under Windows XP combines HTML with Internet technology. The improvement of the user interface makes the use of WinOE software more simple and convenient. The Online Statistical Control (SPC) software package monitors instruments and production samples. This quality control tool reduces production costs and saves a lot of time. Multiple communication methods meet the needs of different users, and analysis results can be transmitted to remote printers or display terminals, and even sent to mobile phones via fax, email, or other means.

The function of ARL direct reading spectrometer 4460
1. A graphical user interface enables navigation, operation, and browsing of HTML pages through Internet Explorer
2. Conventional analysis of unknown samples
3. Quickly enter the analysis program through software shortcuts
4. Automatic analysis program selection
5. Multivariate regression, used to determine the calibration curve
6. Manual input of external results
7. Flexible result display and printing
8. Quality inspection and quality classification
9. Recalculate the results to avoid unnecessary sample reanalysis
10. Result storage and simple post-processing, output to Excel Lotus and others
11. Online SPC Basic instrument control
12. Standardization of Instruments
13. Type standardization
14. Display instrument control results through instrument alarms and status charts
15. Flexible sample definition
16. Password protection for user permissions
17. Software and Instrument Configuration Tools

WinOE software selection options
1. Online Spark DAT
2. ARLnet: LAM network result transmission package
3. Remote sample definition through LAN network
4. Sentry: Sample delivery software
5. Compac: Transmit results to remote computer via serial cable
6. Remote: Transmit the results to the remote terminal through a serial line
7. DIA Monitor: Display analysis results on remote computer software
8. Exam: Receive external combustion analyzer results
9. Metaverage: Analyzing the Average
10. Charge: Furnace charge correction computer
11. SPC Full: Full Image Statistical Process Control Software Package
12. Report: Generate print reports in Thermo or user-defined format
13. DIA2000: Analysis result database and post-processing software package

Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!