VIP member
A8M small boat type switch
Product category: Omron boat shaped switch Product description: A small boat shaped switch that achieves 16A switch performance ▶ Small, 16A switch p
Product details
Contact form |
1-pole single throw type |
2-pole single throw type |
Minimum packaging unit | ||
Button and shell color | black | black | |||
mark | A8MS-1162 | A8MD-1162 | 100 of them | ||
A8MS-1163 | A8MD-1163 |
■ Rated value |
project | Non inductive load (A) | Inductive load (A) | |
Rated voltage (V) | Resistive load | Inductive | motor load |
AC125 | 16 | 16 | 10 |
AC250 | 16 | 16 | 10 |
Note 1 | The inductive load has a power factor of 0.7 or above (AC). |
Note 2 | The load of the electric motor is the load with 6 times the surge current. |
Note 3 | The above rated values are tested under the following conditions. |
(1) Surrounding temperature: 20 ± 2 ℃ (2) Surrounding humidity: 65 ± 5% RH (3) Operating frequency: 7 times/minute |
■ Performance |
Allowable operating frequency | machinery | Below 20 times/min |
electrical | Below 7 times per minute | |
insulation resistance | 100M Ω or above (measured with a DC500V insulation resistance meter) | |
Contact resistance (initial value) | 100MΩThe following (DC6~8V, 1A voltage drop method) | |
withstanding voltage | Terminal - Between terminals | AC2,000V 50/60Hz 1min |
Between terminals and ground | AC4.000V 50/60Hz 1min | |
vibrate | malfunction | 10-55Hz dual amplitude 1.5mm |
impact | malfunction | Maximum 1000m/s2 |
lifetime | machinery | More than 50000 times |
electrical | Over 10000 times | |
Impulse current | Maximum 117A | |
Environmental temperature for use | Temperature -25~+55 ℃, humidity below 60% RH (no freezing or condensation) | |
Environmental humidity for use | Humidity 25-85% RH (+15-35 ℃) | |
weight | 4.5g (1-pole) 5.9g (2-pole) |
A8MS-1162 A8MS-1163 A8MD-1162 A8MD-1163 |
|
Outline processing drawing | ||||||||||||||||||||||
|
||||||||||||||||||||||
The upper surface of the installation panel must be stamped and processed; The upper surface of the installation panel should have an R angle |
Online inquiry