50II Fluke 50II series digital thermometer
Z-small value, Z-large value, and average value with relative time markers provide time reference for major events. Electronic compensation function c
Product details

Product features of Fluke 50II series digital thermometer

  • The reading unit can be º C, º F, or Kelvin (K)
  • The sturdy Fluke 50 II series new contact type handheld thermometer features fast response capability and laboratory accuracy (0.05%+0.3 ° C).
  • Waterproof and dust-proof shell, protective sheath that absorbs impact force
  • Humanized front panel, easy to set up and operate
  • Sleep mode, extending battery life - typical value is 1000 hours
  • Replace the battery without breaking the calibration lead seal
  • By using the optional ToolPak accessory, the thermometer can be hung on any metal object (using a magnet) or on a pipe (using nylon straps and buckles), freeing up both hands
  • 3-year warranty

Configuration of Fluke 50 Series II thermometer:

Model name unit price describe
Fluke 51 II 2600 yuan A single input digital thermometer includes:
  • Anti collision protective cover
  • A 80PK-1 bead probe thermocouple
Fluke 52 II 3180 yuan The dual input digital thermometer includes:
  • Anti collision protective cover
  • Two 80PK-1 bead probe thermocouples
Fluke 53 II 3666 yuan Single input digital thermometer with data recording function, including
  • Anti collision protective cover
  • A 80PK-1 bead probe thermocouple
Fluke 54 II 4200 yuan The dual input digital thermometer includes:
  • Anti collision protective cover
  • Two 80PK-1 bead probe thermocouples

Technical parameters of Fluke 50 Series II thermometer:

Temperature accuracy Above -100 ° C: J, K, T, E, and N types: ± [0.05%+0.3 ° C] * R and S types: ± [0.05%+0.4 ° C]*
Below -100 ° C: J, K, E, and N types: ± [0.20%+0.3 ° C] * T type: ± [0.50%+0.3 ° C
Temperature range J-type:- 210 ° C to 1200 ° C

K-type:- 200 ° C to 1372 ° C
T-shaped:- 250 ° C to 400 ° C
Type E:- 150 ° C to 1000 ° C
N-type:- 200 ° C to 1300 ° C*
R and S types: 0 ° C to 1767 ° C*

Temperature scale ITS-90
Standards NIST-175
display resolution 0.1 °C, 0.1 K < 1000
1°C, 1 K >=1000
pour *Only Fluke 53 II and 54 II thermometers can measure N, R, and S thermocouples

Mechanical and general parameters of Fluke 50 series II thermometer

Overvoltage protection category CSA C22.2 No. 1010.1 1992; EN 61010 Amendments 1,2
Relative humidity (non condensing) 0% to 90%; 0 ° C to 35 ° C
0% to 70%; 0 ° C to 50 ° C
authentication CE, CSA, T Ü V (pending approval)
storage temperature -40 ° C to 60 ° C
operation temperature -10 ° C to 50 ° C
size 173 mm L x 86 mm W x 38 mm
weight 400 g
Battery 3 AA model battery with a typical battery life of 1000 hours