The 4S-CL2 sensor is a constant potential electrolytic chlorine gas sensor. CL2 and O2 undergo corresponding oxidation-reduction reactions at the working electrode and counter electrode, releasing charges to form a current. The magnitude of the current is proportional to the concentration of H2S, and the concentration of chlorine gas can be determined by testing the magnitude of the current.
Sensor characteristics
Low power consumption, high precision, high sensitivity, wide linear range, strong anti-interference ability, excellent repeatability and stability.
Main applications
Widely suitable for the detection of chlorine gas in industrial applications.
TECHNICAL INDEX
Basic performance | |
sensitivity | 600±200nA/ppm |
range | 0~10ppm |
baseline drift | < ± 0.2ppm CL2 equivalent |
Response time (T90) | <60s |
Recovery time (T10) | < 20s (typical value 15s) |
Linearity | linear |
repeatability | <± 2% CL2 equivalent |
Usage environment | |
Working temperature range | -20℃~+50℃ |
Working pressure range | 800~1200mbar |
Operating humidity range | 15%RH~90%RH |
Lifetime warranty | |
Output drift | <20% per year |
service life | 24 months (in the air) |
warranty | 12 months (from the date of shipment) |
Recommended storage temperature | 0-20 ℃ (closed container) |
Electricity | |
resolution | <2ppm |
Recommended load resistor | 33Ω |
Intrinsic safety characteristics | |
2000ppm maximum current | 0.2mA |
Maximum O/C voltage | 1.3V |
Maximum S/C current | <1.0A |
Note: Product parameters are subject to change without prior notice