1、 The principle of 18T/H first stage RO reverse osmosis water treatment system: The first stage RO reverse osmosis water treatment system consists of
Product details

118T/HLevel 1ROThe principle of reverse osmosis water treatment system:

Level 1ROThe reverse osmosis water treatment system consists of pre-treatment andSingle stage reverse osmosis equipmentComposition: The overall material of the equipment is made of stainless steel 304,Primary RO reverse osmosis water treatment systemVery suitable for industries such as food and beverage, the first level RO reverse osmosis water treatment system passes raw water through a multi-media filter, coconut shell type activated carbon filterCation exchangerWait, then apply pressure through a pump and use a reverse osmosis membrane with a pore size of 1/10000 μ m (equivalent to 1/6000 the size of Escherichia coli and 1/300 the size of a virus)(ro membrane)By transforming high concentration water into low concentration water and isolating impurities such as industrial pollutants, heavy metals, bacteria, viruses, etc. that are heavily mixed into the water, the physical and chemical indicators and hygiene standards specified for drinking can be achieved. The water produced by RO reverse osmosis technology has a relatively high purity among the water production technologies currently mastered by humans, with a cleanliness of almost 99%. Therefore, people call this water production machineReverse osmosis purified waterDue to economic cost considerations, most industrial applications do not use stainless steel materials. However, for industries such as food and beverage, or pharmaceuticals, it is recommended to use clean and sterile stainless steel materials as much as possible. It is better to use stainless steel 316 material.

II18T/HLevel 1ROThe process flow of reverse osmosis water treatment system:

Raw water tank - online flocculant dosing device - raw water pump - multi-media filter - activated carbon filter - scale inhibition dosing device - security filter - reverse osmosis main pump -18T/HRO reverse osmosis device - purified water tank

III18T/HLevel 1ROPreparation before the operation of reverse osmosis water treatment system:

As a high-pressure operating equipment, the reverse osmosis membrane (RO) should strictly follow the operating procedures to confirm and adjust the valve opening status for the protection of equipment and instruments and safety reasons before operation. The specific operation is as follows:

1. Open the inlet valve of the security filter and the inlet valve of the high-pressure pump.

2. Open the outlet valve of the high-pressure pump once.

3. Open the inlet valve of the reverse osmosis membrane (RO) once.

4. Rotate the needle valve on the concentrated water pipe three and a half turns.

5. Open the water outlet valve and the concentrated water outlet valve.

6. Close all sampling valves and cleaning valves.

7. Open all pressure display valves to half open position.

418T/HLevel 1ROWhat are the characteristics of the control system for reverse osmosis water treatment system

1. The operation is clear and simple, it can be said to be easy to understand at a glance, fully automatic intelligent control, and can be completed by pressing the switch when needed.

2. After being installed and debugged by professional personnel, it can run normally.

3Reverse osmosis water treatment equipmentIt can achieve fully automated operation, save a lot of manpower, and reduce labor costs.

4. Reverse osmosis equipment has the function of free protection, and under normal operation, there is no need for dedicated personnel to supervise it.

5. Humanized design, a low-pressure protection switch is installed at the inlet of the high-pressure pump. When the pressure of the high-pressure pump drops below 0.05, the pressure controller will activate, causing the equipment to stop working and ensuring the safety of the high-pressure pump and personnel.

6. A slow opening electric valve and a high-pressure switch are installed at the outlet of each high-pressure pump. When the outlet pressure exceeds 2.0Mpa, the pressure controller will activate to stop the equipment and ensure the safety of the high-pressure pump, membrane components, and membrane casing.

7. The body of the reverse osmosis equipment is equipped with various data monitoring, which is clear at a glance

8. Install an online conductivity meter on the main inlet pipe of the reverse osmosis system to monitor the quality of the raw water;

9. Install a pure water flow meter and a concentrated water flow meter on the reverse osmosis device, observe the operation status of reverse osmosis based on the two flow values, and adjust the system recovery rate;


Related searches:How to determine the selection and quantity of reverse osmosis system membranes Operating procedures for reverse osmosis devices Chemical cleaning of reverse osmosis membrane